-- CISCO-IF-CAPABILITY.my: Cisco IF-MIB AGENT-CAPABILITIES
--   
-- February 2004, Yizhong Shen
--   
-- Copyright (c) 1998, 2000, 2002-2004, 2006, 2008
-- by cisco Systems, Inc.
-- All rights reserved.
--   
-- *****************************************************************

CISCO-IF-CAPABILITY DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY
        FROM SNMPv2-SMI
    AGENT-CAPABILITIES
        FROM SNMPv2-CONF
    DisplayString,
    TruthValue
        FROM SNMPv2-TC
    ciscoAgentCapability
        FROM CISCO-SMI;


ciscoIfCapability MODULE-IDENTITY
    LAST-UPDATED    "200803170000Z"
    ORGANIZATION    "Cisco Systems, Inc."
    CONTACT-INFO
            "Cisco Systems
            Customer Service

            Postal: 170 West Tasman Drive
            San Jose, CA  95134
            USA

            Tel: +1 800 553-NETS

            E-mail: cs-snmp@cisco.com
                   cs-lan-switch-snmp@cisco.com"
    DESCRIPTION
        "Agent capabilities for IF-MIB"
    REVISION        "200803170000Z"
    DESCRIPTION
        "Added ciscoIfCapabilityc4710aceVA1R700
        agent capabilities for ACE 4710 Application 
        Control Engine(ACE) Appliance."
    REVISION        "200611030000Z"
    DESCRIPTION
        "Added ciscoIfCapabilityIOSXRV3R4CRS1 agent
        capability for IOS XR 3.4"
    REVISION        "200610300000Z"
    DESCRIPTION
        "Added capability for Cisco TelePresence System (CTS) and
        Cisco TelePresence Manager (CTM) platforms."
    REVISION        "200607170000Z"
    DESCRIPTION
        "Added ciscoIfCapabilityACSWV03R000 agent capabilities
        for Cisco Application Control Software (ACSW) 3.0."
    REVISION        "200602020000Z"
    DESCRIPTION
        "Added  ciscoIfCapabilityIOSXRV2R0CRS1 agent capabilities
        for IOS XR release 2.0."
    REVISION        "200408090000Z"
    DESCRIPTION
        "Added ciscoIfCapabilityV5R015 agent capabilities for MGX
        product series: MPSM Service Module and VXSM (Voice Switch 
        Service Module)."
    REVISION        "200402210000Z"
    DESCRIPTION
        "Added following Agent capabilities for Catalyst
        6000/6500 and Cisco 7600 series devices:

        ciscoIfCapabilityCatOSV08R0101 and
        ciscoIfCapabilityCatOSV08R0301."
    REVISION        "200402200000Z"
    DESCRIPTION
        "Added ciscoIfCapabilityV5R00 agent capabilities for MGX
        product series: MPSM Service Module and VXSM (Voice Switch
        Service Module."
    REVISION        "200303140000Z"
    DESCRIPTION
        "Added following Agent capabilities for MGX product series:

        - ciscoIfCapabilityV4R00 for
          AXSM 10 Gig. Module (AXSM-XG) and 
          AXSM Enhanced Module (AXSM-E)."
    REVISION        "200206120000Z"
    DESCRIPTION
        "Added following Agent capabilities for MGX product series:

        - ciscoIfCapabilityPxmVR200 for 
          PXM(Processor Switch Module) Module

        - ciscoIfCapabilityAxsmVR200 for 
          AXSM(ATM Switch Service Module)

        - ciscoIfCapabilityAxsmeV21R60 for 
          AXSM Enhanced Module.

        - ciscoIfCapabilityFrsm12V3R00 for
          Frame Relay Service Module(FRSM-12)."
    REVISION        "200002090000Z"
    DESCRIPTION
        "Modification of ifCounterDiscontinuityTime,
        ifTableLastChange object and LinkUp/Down trap
        objects."
    REVISION        "9811160000Z"
    DESCRIPTION
        "Initial version of this MIB module."
    ::= { ciscoAgentCapability 125 }



ciscoIfCapabilityV11R03 AGENT-CAPABILITIES
    PRODUCT-RELEASE "Cisco IOS 11.3"
    STATUS          current
    DESCRIPTION
        "IF MIB capabilities"

    SUPPORTS        IF-MIB
    INCLUDES        {
                        ifGeneralInformationGroup,
                        ifStackGroup2,
                        ifFixedLengthGroup,
                        ifHCFixedLengthGroup,
                        ifPacketGroup,
                        ifHCPacketGroup,
                        ifVHCPacketGroup,
                        ifRcvAddressGroup,
                        ifOldObjectsGroup
                    }
    VARIATION       ifTableLastChange
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifAdminStatus
    ACCESS          read-write
    DESCRIPTION
        "Can not be written in case of atm/aal5
        sublayers on an ATM end system, LEC subinterfaces,
        aal5 sublayer of an ATM switch CPU interface,
        ATM 2000 physical interface and lex based interfaces
        used for accounting."

    VARIATION       ifOperStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2),
                        testing(3),
                        unknown(4),
                        dormant(5)
                    }
    DESCRIPTION
        "Unable to detect all states."

    VARIATION       ifLastChange
    ACCESS          read-only
    DESCRIPTION
        "Supported in physical interfaces, lex based interfaces
        used for accounting. In case of subinterfaces, the value
        returned will be the sysuptime when the subinterface
        registered with ifmib."

    VARIATION       ifInOctets
    ACCESS          read-only
    DESCRIPTION
        "Not supported in atm sublayer on an ATM end system.
        Supported in physical interfaces, lex based interfaces,
        aal5 sublayer of an ATM switch CPU interface,
        aal5 sublayer on the atm interfaces of an ATM
        end system, AIP type aal5 sublayer on an ATM
        end system and in frame-relay, x25,
        aflane subinterfaces."

    VARIATION       ifInUcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface, aflane sublayers."

    VARIATION       ifInNUcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Not supported in subinterfaces."

    VARIATION       ifInDiscards
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface, aflane sublayers."

    VARIATION       ifInErrors
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface, aflane sublayers."

    VARIATION       ifInUnknownProtos
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical
        interfaces, lex based interfaces, aal5
        sublayer of an ATM switch CPU interface,
        aflane sublayers."

    VARIATION       ifOutOctets
    ACCESS          read-only
    DESCRIPTION
        "Not supported in atm sublayer on an ATM end system.
        Supported in physical interfaces, lex based interfaces,
        aal5 sublayer of an ATM switch CPU interface,
        aal5 sublayer on the atm interfaces of an ATM
        end system, AIP type aal5 sublayer on an ATM
        end system and in frame-relay, x25,
        aflane subinterfaces."

    VARIATION       ifOutUcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface, aflane sublayers."

    VARIATION       ifOutNUcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Supported in physical interfaces, lex based accounting
        interfaces and in aflane subinterfaces."

    VARIATION       ifOutDiscards
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface, aflane sublayers."

    VARIATION       ifOutErrors
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface, aflane sublayers."

    VARIATION       ifOutQLen
    ACCESS          read-only
    DESCRIPTION
        "Not supported in subinterfaces."

    VARIATION       ifSpecific
    ACCESS          read-only
    DESCRIPTION
        "Not supported in subinterfaces."

    VARIATION       ifInMulticastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifInBroadcastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifOutMulticastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifOutBroadcastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifHCInOctets
    ACCESS          read-only
    DESCRIPTION
        "Supported in LEC sublayers only."

    VARIATION       ifHCInUcastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifHCInMulticastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifHCInBroadcastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifHCOutOctets
    ACCESS          read-only
    DESCRIPTION
        "Supported in LEC sublayers only."

    VARIATION       ifHCOutUcastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifHCOutMulticastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifHCOutBroadcastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifLinkUpDownTrapEnable
    ACCESS          read-write
    DESCRIPTION
        "Only physical interfaces can have link traps enabled.
        Hardwired on subinterfaces and on lex based interfaces
        used for accounting to be false."

    VARIATION       ifPromiscuousMode
    SYNTAX          TruthValue
    ACCESS          read-only
    DESCRIPTION
        "Not writable, hardcoded to false (2)."

    VARIATION       ifConnectorPresent
    ACCESS          read-only
    DESCRIPTION
        "Hardcoded to be true for controller
        type sub-interfaces and to be false for
        all other sub-interfaces."

    VARIATION       ifAlias
    SYNTAX          DisplayString (SIZE (0..64))
    ACCESS          read-write
    DESCRIPTION
        "For interfaces that are not being nv written,
        the ifAlias value is lost when the system is
        reloaded."

    VARIATION       ifCounterDiscontinuityTime
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifStackStatus
    SYNTAX          INTEGER  {
                        active(1)
                    }
    ACCESS          read-only
    DESCRIPTION
        "Write/create not supported.
        Unable to detect all states."

    VARIATION       ifRcvAddressAddress
    DESCRIPTION
        "Read-only access is added to this object.
        Supported in physical interfaces, lex based
        interfaces and in lec sublayers."

    VARIATION       ifRcvAddressStatus
    SYNTAX          INTEGER  {
                        active(1)
                    }
    ACCESS          read-only
    DESCRIPTION
        "Write/create not supported. Unable to detect
        all states.  Supported in physical interfaces,
        lex based interfaces and in lec sublayers."

    VARIATION       ifRcvAddressType
    SYNTAX          INTEGER  {
                        other(1)
                    }
    ACCESS          read-only
    DEFVAL          { other }
    DESCRIPTION
        "Write/create not supported. Unable to detect
        all states.  Default value is { other }.
        Supported in physical interfaces,
        lex based interfaces and in lec sublayers."

    VARIATION       ifTestId
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestStatus
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestType
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestResult
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestCode
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestOwner
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       linkUp
    DESCRIPTION
        "A linkUp trap signifies that the sending
        protocol entity recognizes that one of the
        communication links represented in the agent's
        configuration has come up."

    VARIATION       linkDown
    DESCRIPTION
        "A linkDown trap signifies that the sending
        protocol entity recognizes a failure in one of
        the communication links represented in the
        agent's configuration."

    ::= { ciscoIfCapability 1 }

ciscoIfCapabilityV12R00 AGENT-CAPABILITIES
    PRODUCT-RELEASE "Cisco IOS 12.0"
    STATUS          current
    DESCRIPTION
        "IF MIB capabilities"

    SUPPORTS        IF-MIB
    INCLUDES        {
                        ifGeneralInformationGroup,
                        ifStackGroup2,
                        ifFixedLengthGroup,
                        ifHCFixedLengthGroup,
                        ifPacketGroup,
                        ifHCPacketGroup,
                        ifVHCPacketGroup,
                        ifRcvAddressGroup,
                        ifOldObjectsGroup
                    }
    VARIATION       ifTableLastChange
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifAdminStatus
    ACCESS          read-write
    DESCRIPTION
        "Can not be written in case of atm/aal5 sublayers
        on an ATM end system, LEC subinterfaces, aal5
        sublayer of an ATM switch CPU interface, ATM 2000
        physical interface and lex based interfaces used
        for accounting."

    VARIATION       ifOperStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2),
                        testing(3),
                        unknown(4),
                        dormant(5)
                    }
    DESCRIPTION
        "Unable to detect all states."

    VARIATION       ifLastChange
    ACCESS          read-only
    DESCRIPTION
        "Supported in physical interfaces, lex based interfaces
        used for accounting and in cable, mc3810_dsx1, voice
        subinterfaces."

    VARIATION       ifInOctets
    ACCESS          read-only
    DESCRIPTION
        "Not supported in atm sublayer on an ATM
        end system.  Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an
        ATM switch CPU interface,  aal5 sublayer on
        the atm interfaces of an ATM end system,
        AIP type aal5 sublayer on an ATM end system and in
        frame-relay, x25, aflane, cable subinterfaces."

    VARIATION       ifInUcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface and in aflane, cable
        subinterfaces."

    VARIATION       ifInNUcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Not supported in subinterfaces."

    VARIATION       ifInDiscards
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface and in aflane,
        cable subinterfaces."

    VARIATION       ifInErrors
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface and in aflane,
        cable subinterfaces."

    VARIATION       ifInUnknownProtos
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface and in aflane,
        cable subinterfaces."

    VARIATION       ifOutOctets
    ACCESS          read-only
    DESCRIPTION
        "Not supported in atm sublayer on an ATM end system.
        Supported in physical interfaces, lex based interfaces,
        aal5 sublayer of an ATM switch CPU interface,
        aal5 sublayer on the atm interfaces of an ATM
        end system, AIP type aal5 sublayer on an ATM
        end system and in frame-relay, x25, aflane,
        cable subinterfaces."

    VARIATION       ifOutUcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface and in aflane,
        cable subinterfaces."

    VARIATION       ifOutNUcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Supported in physical interfaces, lex based accounting
        interfaces and in aflane subinterfaces."

    VARIATION       ifOutDiscards
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface and in aflane,
        cable subinterfaces."

    VARIATION       ifOutErrors
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface and in aflane,
        cable subinterfaces."

    VARIATION       ifOutQLen
    ACCESS          read-only
    DESCRIPTION
        "Not supported in subinterfaces."

    VARIATION       ifSpecific
    ACCESS          read-only
    DESCRIPTION
        "Not supported in subinterfaces."

    VARIATION       ifInMulticastPkts
    ACCESS          read-only
    DESCRIPTION
        "Supported in cable subinterface."

    VARIATION       ifInBroadcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Supported in cable subinterface."

    VARIATION       ifOutMulticastPkts
    ACCESS          read-only
    DESCRIPTION
        "Supported in cable subinterface."

    VARIATION       ifOutBroadcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Supported in cable subinterface."

    VARIATION       ifHCInOctets
    ACCESS          read-only
    DESCRIPTION
        "Supported in physical interfaces and
        LEC sub-layers."

    VARIATION       ifHCInUcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Supported in physical interfaces."

    VARIATION       ifHCInMulticastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifHCInBroadcastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifHCOutOctets
    ACCESS          read-only
    DESCRIPTION
        "Supported in physical interfaces and
        in LEC sub-layers."

    VARIATION       ifHCOutUcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Supported in physical interfaces."

    VARIATION       ifHCOutMulticastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifHCOutBroadcastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifLinkUpDownTrapEnable
    ACCESS          read-write
    DESCRIPTION
        "Physical interfaces and subinterfaces can have link
        traps enabled. Write not supported in lex based
        interfaces used for accounting and the object is
        hardwired to be false."

    VARIATION       ifPromiscuousMode
    SYNTAX          TruthValue
    ACCESS          read-only
    DESCRIPTION
        "Not writable, hardcoded to false (2)."

    VARIATION       ifConnectorPresent
    ACCESS          read-only
    DESCRIPTION
        "Hardcoded to be false on lex based interfaces
        used for accounting."

    VARIATION       ifAlias
    SYNTAX          DisplayString (SIZE (0..64))
    ACCESS          read-write
    DESCRIPTION
        "For interfaces that are not being nv written,
        the ifAlias value is lost when the system
        is reloaded."

    VARIATION       ifCounterDiscontinuityTime
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifStackStatus
    SYNTAX          INTEGER  {
                        active(1)
                    }
    ACCESS          read-only
    DESCRIPTION
        "Write/create not supported.
        Unable to detect all states."

    VARIATION       ifRcvAddressAddress
    DESCRIPTION
        "Read-only access is added to this object.
        Supported in physical interfaces,
        lex based interfaces and in lec
        sublayers."

    VARIATION       ifRcvAddressStatus
    SYNTAX          INTEGER  {
                        active(1)
                    }
    ACCESS          read-only
    DESCRIPTION
        "Write/create not supported. Unable to
        detect all states.  Supported in physical
        interfaces, lex based interfaces and in
        lec sublayers."

    VARIATION       ifRcvAddressType
    SYNTAX          INTEGER  {
                        other(1)
                    }
    ACCESS          read-only
    DEFVAL          { other }
    DESCRIPTION
        "Write/create not supported. Unable to detect
        all states.  Default value is { other }.
        Supported in physical interfaces, lex based
        interfaces and in lec sublayers."

    VARIATION       ifTestId
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestStatus
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestType
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestResult
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestCode
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestOwner
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       linkUp
    DESCRIPTION
        "A linkUp trap signifies that the sending
        protocol entity recognizes that one of the
        communication links represented in the agent's
        configuration has come up."

    VARIATION       linkDown
    DESCRIPTION
        "A linkDown trap signifies that the sending
        protocol entity recognizes a failure in one of
        the communication links represented in the
        agent's configuration."

    ::= { ciscoIfCapability 2 }

ciscoIfCapabilityV12R01T AGENT-CAPABILITIES
    PRODUCT-RELEASE "Cisco IOS 12.1T"
    STATUS          current
    DESCRIPTION
        "IF MIB capabilities"

    SUPPORTS        IF-MIB
    INCLUDES        {
                        ifGeneralInformationGroup,
                        ifStackGroup2,
                        ifFixedLengthGroup,
                        ifHCFixedLengthGroup,
                        ifPacketGroup,
                        ifHCPacketGroup,
                        ifVHCPacketGroup,
                        ifRcvAddressGroup,
                        ifOldObjectsGroup
                    }
    VARIATION       ifTableLastChange
    ACCESS          not-implemented
    DESCRIPTION
        "OIR instances need to be modified"

    VARIATION       ifAdminStatus
    ACCESS          read-write
    DESCRIPTION
        "Can not be written in case of atm/aal5 sublayers
        on an ATM end system, LEC subinterfaces, aal5
        sublayer of an ATM switch CPU interface, ATM 2000
        physical interface and lex based interfaces
        used for accounting."

    VARIATION       ifOperStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2),
                        testing(3),
                        unknown(4),
                        dormant(5)
                    }
    DESCRIPTION
        "Unable to detect all states."

    VARIATION       ifLastChange
    ACCESS          read-only
    DESCRIPTION
        "Supported in physical interfaces, lex based
        interfaces used for accounting and in cable,
        mc3810_dsx1, voice subinterfaces."

    VARIATION       ifInOctets
    ACCESS          read-only
    DESCRIPTION
        "Not supported in atm sublayer on an ATM end system.
        Supported in physical interfaces, lex based interfaces,
        aal5 sublayer of an ATM switch CPU interface,
        aal5 sublayer on the atm interfaces of an ATM
        end system, AIP type aal5 sublayer on an ATM
        end system and in frame-relay, x25,
        aflane, cable subinterfaces."

    VARIATION       ifInUcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface and in aflane,
        cable subinterfaces."

    VARIATION       ifInNUcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Not supported in subinterfaces."

    VARIATION       ifInDiscards
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface and in aflane,
        cable subinterfaces."

    VARIATION       ifInErrors
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface and in aflane,
        cable subinterfaces."

    VARIATION       ifInUnknownProtos
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface and in aflane,
        cable subinterfaces."

    VARIATION       ifOutOctets
    ACCESS          read-only
    DESCRIPTION
        "Not supported in atm sublayer on an ATM end system.
        Supported in physical interfaces, lex based interfaces,
        aal5 sublayer of an ATM switch CPU interface,
        aal5 sublayer on the atm interfaces of an
        ATM end system, AIP type aal5 sublayer on an
        ATM end system and in frame-relay, x25,
        aflane, cable subinterfaces."

    VARIATION       ifOutUcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface and in aflane,
        cable subinterfaces."

    VARIATION       ifOutNUcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Supported in physical interfaces, lex based
        accounting interfaces and in aflane subinterfaces."

    VARIATION       ifOutDiscards
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface and in aflane,
        cable subinterfaces."

    VARIATION       ifOutErrors
    ACCESS          read-only
    DESCRIPTION
        "Not supported in frame-relay subinterfaces,
        x25 subinterfaces, atm/aal5 sublayers on an
        ATM end system. Supported in physical interfaces,
        lex based interfaces, aal5 sublayer of an ATM
        switch CPU interface and in aflane,
        cable subinterfaces."

    VARIATION       ifOutQLen
    ACCESS          read-only
    DESCRIPTION
        "Not supported in subinterfaces."

    VARIATION       ifSpecific
    ACCESS          read-only
    DESCRIPTION
        "Not supported in subinterfaces."

    VARIATION       ifInMulticastPkts
    ACCESS          read-only
    DESCRIPTION
        "Supported in cable subinterface."

    VARIATION       ifInBroadcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Supported in cable subinterface."

    VARIATION       ifOutMulticastPkts
    ACCESS          read-only
    DESCRIPTION
        "Supported in cable subinterface."

    VARIATION       ifOutBroadcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Supported in cable subinterface."

    VARIATION       ifHCInOctets
    ACCESS          read-only
    DESCRIPTION
        "Supported in physical interfaces and
        LEC sub-layers."

    VARIATION       ifHCInUcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Supported in physical interfaces."

    VARIATION       ifHCInMulticastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifHCInBroadcastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifHCOutOctets
    ACCESS          read-only
    DESCRIPTION
        "Supported in physical interfaces and
        in LEC sub-layers."

    VARIATION       ifHCOutUcastPkts
    ACCESS          read-only
    DESCRIPTION
        "Supported in physical interfaces."

    VARIATION       ifHCOutMulticastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifHCOutBroadcastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifLinkUpDownTrapEnable
    ACCESS          read-write
    DESCRIPTION
        "Physical interfaces and subinterfaces can have link
        traps enabled. Write not supported in lex based
        interfaces used for accounting and the object is
        hardwired to be false."

    VARIATION       ifPromiscuousMode
    SYNTAX          TruthValue
    ACCESS          read-only
    DESCRIPTION
        "Not writable, hardcoded to false (2)."

    VARIATION       ifConnectorPresent
    ACCESS          read-only
    DESCRIPTION
        "Hardcoded to be false on lex based
        interfaces used for accounting."

    VARIATION       ifAlias
    SYNTAX          DisplayString (SIZE (0..64))
    ACCESS          read-write
    DESCRIPTION
        "For interfaces that are not being nv written,
        the ifAlias value is lost when the system
        is reloaded."

    VARIATION       ifStackStatus
    SYNTAX          INTEGER  {
                        active(1)
                    }
    ACCESS          read-only
    DESCRIPTION
        "Write/create not supported.
        Unable to detect all states."

    VARIATION       ifRcvAddressAddress
    DESCRIPTION
        "Read-only access is added to this object.
        Supported in physical interfaces, lex based
        interfaces and in lec sublayers."

    VARIATION       ifRcvAddressStatus
    SYNTAX          INTEGER  {
                        active(1)
                    }
    ACCESS          read-only
    DESCRIPTION
        "Write/create not supported. Unable to detect
        all states.  Supported in physical interfaces,
        lex based interfaces and in lec sublayers."

    VARIATION       ifRcvAddressType
    SYNTAX          INTEGER  {
                        other(1)
                    }
    ACCESS          read-only
    DEFVAL          { other }
    DESCRIPTION
        "Write/create not supported. Unable to detect
        all states.  Default value is { other }.
        Supported in physical interfaces,
        lex based interfaces and in lec sublayers."

    VARIATION       ifTestId
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestStatus
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestType
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestResult
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestCode
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestOwner
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       linkUp
    DESCRIPTION
        "A linkUp trap signifies that the sending
        protocol entity recognizes that one of the
        communication links represented in the agent's
        configuration has come up. When a new config
        command 'snmp-server trap link ietf' is set, the
        varbind list is made of objects specified here.
        Otherwise, the varbind list defined in the
        previous version holds good. For sub-interfaces,
        as there is no support for locIfReason, it will
        be omitted from the trap message."

    VARIATION       linkDown
    DESCRIPTION
        "A linkDown trap signifies that the sending
        protocol entity recognizes a failure in one of
        the communication links represented in the
        agent's configuration. When a new config
        command 'snmp-server trap link ietf' is set, the
        varbind list is made of objects specified here.
        Otherwise, the varbind list defined in the
        previous version holds good. For sub-interfaces,
        as there is no support for locIfReason, it will
        be omitted from the trap message."

    ::= { ciscoIfCapability 3 }

ciscoIfCapabilityPxmVR200 AGENT-CAPABILITIES
    PRODUCT-RELEASE "MGX8850 Release 2.00,BPX SES Release 1.00."
    STATUS          current
    DESCRIPTION
        "IF MIB capabilities for PXM45, PXM1 Modules."

    SUPPORTS        IF-MIB
    INCLUDES        {
                        ifGeneralInformationGroup,
                        ifPacketGroup
                    }
    VARIATION       ifTableLastChange
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifAdminStatus
    DESCRIPTION
        "This object can not be written in case of
        rs232 interface identified by ifType
        value rs232(33)."

    VARIATION       ifOperStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2),
                        testing(3)
                    }
    DESCRIPTION
        "Unable to detect all states."

    VARIATION       ifLastChange
    DESCRIPTION
        "The value does not reflect the change in
        the operational status of the interface.
        The value zero is returned."

    VARIATION       ifInOctets
    DESCRIPTION
        "Supported only for following interfaces:
        Ethernet interface (ifType = ethernetCsmacd(6))
        Loopback interfce  (ifType = softwareLoopback(24))
        SLIP Interface (ifType = slip(28))."

    VARIATION       ifInUcastPkts
    DESCRIPTION
        "Supported only for following interfaces:
        Ethernet interface (ifType = ethernetCsmacd(6))
        Loopback interfce  (ifType = softwareLoopback(24))
        SLIP Interface (ifType = slip(28))."

    VARIATION       ifInDiscards
    DESCRIPTION
        "Supported only for following interfaces:
        Ethernet interface (ifType = ethernetCsmacd(6))
        Loopback interfce  (ifType = softwareLoopback(24))
        SLIP Interface (ifType = slip(28))."

    VARIATION       ifInErrors
    DESCRIPTION
        "Supported only for following interfaces:
        Ethernet interface (ifType = ethernetCsmacd(6))
        Loopback interfce  (ifType = softwareLoopback(24))
        SLIP Interface (ifType = slip(28))."

    VARIATION       ifInUnknownProtos
    DESCRIPTION
        "Supported only for following interfaces:
        Ethernet interface (ifType = ethernetCsmacd(6))
        Loopback interfce  (ifType = softwareLoopback(24))
        SLIP Interface (ifType = slip(28))."

    VARIATION       ifOutOctets
    DESCRIPTION
        "Supported only for following interfaces:
        Ethernet interface (ifType = ethernetCsmacd(6))
        Loopback interfce  (ifType = softwareLoopback(24))
        SLIP Interface (ifType = slip(28))."

    VARIATION       ifOutUcastPkts
    DESCRIPTION
        "Supported only for following interfaces:
        Ethernet interface (ifType = ethernetCsmacd(6))
        Loopback interfce  (ifType = softwareLoopback(24))
        SLIP Interface (ifType = slip(28))."

    VARIATION       ifOutDiscards
    DESCRIPTION
        "Supported only for following interfaces:
        Ethernet interface (ifType = ethernetCsmacd(6))
        Loopback interfce  (ifType = softwareLoopback(24))
        SLIP Interface (ifType = slip(28))."

    VARIATION       ifOutErrors
    DESCRIPTION
        "Supported only for following interfaces:
        Ethernet interface (ifType = ethernetCsmacd(6))
        Loopback interfce  (ifType = softwareLoopback(24))
        SLIP Interface (ifType = slip(28))."

    VARIATION       ifInMulticastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifInBroadcastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifOutMulticastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifOutBroadcastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifLinkUpDownTrapEnable
    ACCESS          read-only
    DEFVAL          { disabled }
    DESCRIPTION
        "Write operation not supported."

    VARIATION       ifPromiscuousMode
    ACCESS          read-only
    DEFVAL          { false }
    DESCRIPTION
        "Write operation not supported."

    VARIATION       ifAlias
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    ::= { ciscoIfCapability 4 }

ciscoIfCapabilityAxsmVR200 AGENT-CAPABILITIES
    PRODUCT-RELEASE "MGX8850 Release 2.00."
    STATUS          current
    DESCRIPTION
        "IF MIB capabilities for ATM Switch Service
        Module(AXSM)."

    SUPPORTS        IF-MIB
    INCLUDES        { ifGeneralInformationGroup }
    VARIATION       ifNumber
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifTableLastChange
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifPhysAddress
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifAdminStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2)
                    }
    DESCRIPTION
        "This object can not be written in case of
        atm interface identified by ifType value atm(37).
        Does not support testing(3)."

    VARIATION       ifOperStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2),
                        notPresent(6)
                    }
    DESCRIPTION
        "Unable to detect all states.
        Does not support testing(3),unknown(4),
        dormant(5),lowerLayerDown(7)."

    VARIATION       ifLastChange
    DESCRIPTION
        "The value does not reflect the change in
        the operational status of the interface.
        The value zero is returned."

    VARIATION       ifLinkUpDownTrapEnable
    ACCESS          read-only
    DEFVAL          { disabled }
    DESCRIPTION
        "Write operation not supported."

    VARIATION       ifAlias
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    ::= { ciscoIfCapability 5 }

ciscoIfCapabilityAxsmeV21R60 AGENT-CAPABILITIES
    PRODUCT-RELEASE "MGX8850 Release 2.1.60"
    STATUS          current
    DESCRIPTION
        "IF MIB capabilities for Enhanced ATM
        Switch Service Module (AXSM-E)."

    SUPPORTS        IF-MIB
    INCLUDES        { ifGeneralInformationGroup }
    VARIATION       ifNumber
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifTableLastChange
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifPhysAddress
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifAdminStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2)
                    }
    DESCRIPTION
        "Does not support testing(3)."

    VARIATION       ifOperStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2),
                        notPresent(6),
                        lowerLayerDown(7)
                    }
    DESCRIPTION
        "Unable to detect all states.
        Does not support testing(3),
        unknown(4), dormant(5)."

    VARIATION       ifLastChange
    DESCRIPTION
        "The value does not reflect the change in
        the operational status of the interface.
        The value zero is returned."

    VARIATION       ifLinkUpDownTrapEnable
    ACCESS          read-only
    DEFVAL          { disabled }
    DESCRIPTION
        "Write operation not supported."

    VARIATION       ifAlias
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    ::= { ciscoIfCapability 6 }

ciscoIfCapabilityFrsm12V3R00 AGENT-CAPABILITIES
    PRODUCT-RELEASE "MGX8850 Release 3.0.00"
    STATUS          current
    DESCRIPTION
        "IF MIB capabilities for
        Frame Relay Service Module(FRSM-12)."

    SUPPORTS        IF-MIB
    INCLUDES        { ifGeneralInformationGroup }
    VARIATION       ifNumber
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifTableLastChange
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifPhysAddress
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifAdminStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2)
                    }
    DESCRIPTION
        "Does not support testing(3)."

    VARIATION       ifOperStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2),
                        notPresent(6),
                        lowerLayerDown(7)
                    }
    DESCRIPTION
        "Unable to detect all states.
        Does not support testing(3),
        unknown(4), dormant(5)."

    VARIATION       ifLastChange
    DESCRIPTION
        "The value does not reflect the change in
        the operational status of the interface.
        The value zero is returned."

    VARIATION       ifLinkUpDownTrapEnable
    ACCESS          read-only
    DEFVAL          { disabled }
    DESCRIPTION
        "Write operation not supported."

    VARIATION       ifAlias
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    ::= { ciscoIfCapability 7 }

ciscoIfCapabilityV4R00 AGENT-CAPABILITIES
    PRODUCT-RELEASE "MGX8950, MGX8850 Release 4.0.00"
    STATUS          current
    DESCRIPTION
        "IF MIB capabilities for 10 Gig. ATM
        Switch Service Module (AXSM-XG) and 
        Enhanced ATM Switch Service Module 
        (AXSM-E)."

    SUPPORTS        IF-MIB
    INCLUDES        { ifGeneralInformationGroup }
    VARIATION       ifOperStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2),
                        testing(3),
                        notPresent(6),
                        lowerLayerDown(7)
                    }
    DESCRIPTION
        "Only subset of values supported.
        Following values not supported:
        unknown(4), dormant(5)."

    VARIATION       ifOperStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2),
                        notPresent(6),
                        lowerLayerDown(7)
                    }
    DESCRIPTION
        "Only subset of values supported.
        Following values not supported:
        testing(3), unknown(4), dormant(5)."

    VARIATION       ifNumber
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifTableLastChange
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifPhysAddress
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifAdminStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2)
                    }
    DESCRIPTION
        "Does not support testing(3)."

    VARIATION       ifLastChange
    DESCRIPTION
        "The value does not reflect the change in
        the operational status of the interface.
        The value zero is returned."

    VARIATION       ifLinkUpDownTrapEnable
    ACCESS          read-only
    DEFVAL          { disabled }
    DESCRIPTION
        "Write operation not supported."

    VARIATION       ifAlias
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    ::= { ciscoIfCapability 8 }

ciscoIfCapabilityV5R00 AGENT-CAPABILITIES
    PRODUCT-RELEASE "MGX8850 Release 5.0.0"
    STATUS          current
    DESCRIPTION
        "IF MIB capabilities for Voice Switch
        Service Module (VXSM) and MPSM in 
        release 5.0.0"

    SUPPORTS        IF-MIB
    INCLUDES        { ifGeneralInformationGroup }
    VARIATION       ifTableLastChange
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifPhysAddress
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifNumber
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifAdminStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2)
                    }
    DESCRIPTION
        "For ifType propAtm (197), only up(1) is supported.
        This object is not supported if the
        ifType is sonetVT(51)."

    VARIATION       ifOperStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2)
                    }
    DESCRIPTION
        "For ifType propAtm (197), not all states
        can be detected.
        This object is not supported if the ifType
        is sonetVT(51) or propAtm (197)."

    VARIATION       ifOperStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2),
                        testing(3),
                        notPresent(6),
                        lowerLayerDown(7)
                    }
    DESCRIPTION
        "For ifType propAtm (197), not all states
        can be detected.
        For ifType sonetVT(51) only up(1), down(2) and
        lowerLayerDown(7) are detected."

    VARIATION       ifLastChange
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifLastChange
    DESCRIPTION
        "The value does not reflect the change in
        the operational status of the interface.
        The value zero is returned."

    VARIATION       ifLinkUpDownTrapEnable
    ACCESS          read-only
    DEFVAL          { disabled }
    DESCRIPTION
        "Write operation not supported."

    ::= { ciscoIfCapability 9 }

ciscoIfCapabilityCatOSV08R0101 AGENT-CAPABILITIES
    PRODUCT-RELEASE "Cisco CatOS 8.1(1) on Catalyst 6000/6500
                         and Cisco 7600 series devices."
    STATUS          current
    DESCRIPTION
        "IF MIB agent capabilities."

    SUPPORTS        IF-MIB
    INCLUDES        {
                        ifGeneralInformationGroup,
                        ifStackGroup2,
                        ifFixedLengthGroup,
                        ifHCFixedLengthGroup,
                        ifPacketGroup,
                        ifHCPacketGroup,
                        ifVHCPacketGroup,
                        ifOldObjectsGroup,
                        ifCounterDiscontinuityGroup,
                        linkUpDownNotificationsGroup,
                        ifGeneralGroup,
                        ifStackGroup
                    }
    VARIATION       ifAdminStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2)
                    }
    DESCRIPTION
        "Set operations are not allowed on VLAN
        interfaces, EtherChannel interfaces,
        subinterfaces, and ports of network
        service modules."

    VARIATION       ifOperStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2),
                        dormant(5),
                        lowerLayerDown(7)
                    }
    DESCRIPTION
        "Always returns up(1) for VLAN interfaces."

    VARIATION       ifInOctets
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces."

    VARIATION       ifInUcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces."

    VARIATION       ifInNUcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces."

    VARIATION       ifInDiscards
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces."

    VARIATION       ifInErrors
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces."

    VARIATION       ifInUnknownProtos
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces."

    VARIATION       ifOutOctets
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces."

    VARIATION       ifOutUcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces."

    VARIATION       ifOutNUcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces."

    VARIATION       ifOutDiscards
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces."

    VARIATION       ifOutErrors
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces."

    VARIATION       ifOutQLen
    DESCRIPTION
        "Hardcoded to zero."

    VARIATION       ifSpecific
    DESCRIPTION
        "Hardcoded to nullOID."

    VARIATION       ifInMulticastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces and
        switch management interfaces, i.e.,
        the in-band interfaces(sc0 and sc1) and
        the out-of-band management serial line
        internet protocol(SLIP) interface(sl0)."

    VARIATION       ifInBroadcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces and
        switch management interfaces."

    VARIATION       ifOutMulticastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces and
        switch management interfaces."

    VARIATION       ifOutBroadcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces and
        switch management interfaces."

    VARIATION       ifHCInOctets
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces."

    VARIATION       ifHCInUcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces."

    VARIATION       ifHCInMulticastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces."

    VARIATION       ifHCInBroadcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces."

    VARIATION       ifHCOutOctets
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces."

    VARIATION       ifHCOutUcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces."

    VARIATION       ifHCOutMulticastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces."

    VARIATION       ifHCOutBroadcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces."

    VARIATION       ifLinkUpDownTrapEnable
    DESCRIPTION
        "Set operations are not allowed on VLAN
        interfaces, ports of network service
        modules and subinterfaces."

    VARIATION       ifPromiscuousMode
    DESCRIPTION
        "Set operations are not allowed."

    VARIATION       ifAlias
    DESCRIPTION
        "Set operations not allowed on subinterfaces."

    VARIATION       ifStackStatus
    SYNTAX          INTEGER  {
                        active(1)
                    }
    ACCESS          read-only
    DESCRIPTION
        "Supported for EtherChannel interfaces only.
        Unable to detect all states.
        Set operations are not allowed."

    VARIATION       ifRcvAddressStatus
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifRcvAddressEntry not supported."

    VARIATION       ifRcvAddressType
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifRcvAddressEntry not supported."

    VARIATION       ifTestId
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestStatus
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestType
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestResult
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestCode
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestOwner
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       linkUp
    DESCRIPTION
        "The instance value for ifName is appended
        in addition to the regular varbinds."

    VARIATION       linkDown
    DESCRIPTION
        "The instance values of
        portSecurityOperStatus and
        portSecurityLastSrcAddr are appended in
        case of port security issues, and the
        instance value of portAdditionalOperStatus
        upon port errordisable issues."

    ::= { ciscoIfCapability 10 }

ciscoIfCapabilityCatOSV08R0301 AGENT-CAPABILITIES
    PRODUCT-RELEASE "Cisco CatOS 8.3(1) on Catalyst 6000/6500
                         and Cisco 7600 series devices."
    STATUS          current
    DESCRIPTION
        "IF MIB agent capabilities."

    SUPPORTS        IF-MIB
    INCLUDES        {
                        ifGeneralInformationGroup,
                        ifStackGroup2,
                        ifFixedLengthGroup,
                        ifHCFixedLengthGroup,
                        ifPacketGroup,
                        ifHCPacketGroup,
                        ifVHCPacketGroup,
                        ifOldObjectsGroup,
                        ifCounterDiscontinuityGroup,
                        linkUpDownNotificationsGroup,
                        ifGeneralGroup,
                        ifStackGroup
                    }
    VARIATION       ifMtu
    DESCRIPTION
        "Hardcoded to zero for the inband port."

    VARIATION       ifPhysAddress
    DESCRIPTION
        "Hardcoded to '00 00 00 00 00 00' for the
        inband port."

    VARIATION       ifAdminStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2)
                    }
    DESCRIPTION
        "Set operations are not allowed on VLANs,
        EtherChannel interfaces, the inband port,
        subinterfaces, and ports of network
        service modules."

    VARIATION       ifOperStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2),
                        dormant(5),
                        lowerLayerDown(7)
                    }
    DESCRIPTION
        "Always returns up(1) for the inband port
        and VLAN interfaces."

    VARIATION       ifInOctets
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces
        if PFC(Policy Feature Card) 1 is used.
        Hardcoded to zero for the inband port."

    VARIATION       ifInUcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces if
        PFC 1 is used. Not instantiated for the
        inband port."

    VARIATION       ifInNUcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces if
        PFC 1 is used. Not instantiated for the
        inband port."

    VARIATION       ifInDiscards
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces. Not
        instantiated for the inband port."

    VARIATION       ifInErrors
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces. Not
        instantiated for the inband port."

    VARIATION       ifInUnknownProtos
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces. Not
        instantiated for the inband port."

    VARIATION       ifOutOctets
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces if
        PFC 1 or PFC 2 is used. Not instantiated for
        the inband port."

    VARIATION       ifOutUcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces if
        PFC 1 is used. Not instantiated for the
        inband port."

    VARIATION       ifOutNUcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces if
        PFC 1 or PFC 2 is used. Not instantiated for
        the inband port."

    VARIATION       ifOutDiscards
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces. Not
        instantiated for the inband port."

    VARIATION       ifOutErrors
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces. Not
        instantiated for the inband port."

    VARIATION       ifOutQLen
    DESCRIPTION
        "Hardcoded to zero."

    VARIATION       ifSpecific
    DESCRIPTION
        "Hardcoded to nullOID."

    VARIATION       ifInMulticastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces and
        switch management interfaces. Not
        instantiated for the inband port."

    VARIATION       ifInBroadcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces and
        switch management interfaces. Not
        instantiated for the inband port."

    VARIATION       ifOutMulticastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces and
        switch management interfaces. Not
        instantiated for the inband port."

    VARIATION       ifOutBroadcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces and
        switch management interfaces. Not
        instantiated for the inband port."

    VARIATION       ifHCInOctets
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces if
        PFC 1 is used. Not instantiated for the
        inband port."

    VARIATION       ifHCInUcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces if
        PFC 1 in use. Not instantiated for the
        inband port."

    VARIATION       ifHCInMulticastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces. Not
        instantiated for the inband port."

    VARIATION       ifHCInBroadcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces. Not
        instantiated for the inband port."

    VARIATION       ifHCOutOctets
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces if
        PFC 1 or PFC 2 is used. Not instantiated for
        the inband port."

    VARIATION       ifHCOutUcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces if
        PFC 1 is used. Not instantiated for the
        inband port."

    VARIATION       ifHCOutMulticastPkts
    DESCRIPTION
        "Not instantiated for the inband port."

    VARIATION       ifHCOutBroadcastPkts
    DESCRIPTION
        "Hardcoded to zero for VLAN interfaces. Not
        instantiated for the inband port."

    VARIATION       ifLinkUpDownTrapEnable
    DESCRIPTION
        "Not instantiated for the inband port.
        Set operations are not allowed on VLAN
        interfaces, ports of network service
        modules and subinterfaces."

    VARIATION       ifHighSpeed
    DESCRIPTION
        "Hardcoded to zero for the inband port."

    VARIATION       ifPromiscuousMode
    DESCRIPTION
        "Set operations are not allowed."

    VARIATION       ifAlias
    DESCRIPTION
        "Always returns an empty string for the
        inband port. Set operations not allowed on
        subinterfaces and the inband port."

    VARIATION       ifStackStatus
    SYNTAX          INTEGER  {
                        active(1)
                    }
    ACCESS          read-only
    DESCRIPTION
        "Supported for EtherChannel interfaces only.
        Unable to detect all states.
        Set operations are not allowed."

    VARIATION       ifRcvAddressStatus
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifRcvAddressEntry not supported."

    VARIATION       ifRcvAddressType
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifRcvAddressEntry not supported."

    VARIATION       ifTestId
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestStatus
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestType
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestResult
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestCode
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       ifTestOwner
    ACCESS          not-implemented
    DESCRIPTION
        "Table for ifTestEntry not supported."

    VARIATION       linkUp
    DESCRIPTION
        "The instance value for ifName is appended
        in addition to the regular varbinds."

    VARIATION       linkDown
    DESCRIPTION
        "The instance values of
        portSecurityOperStatus and
        portSecurityLastSrcAddr are appended in
        case of port security issues, and the
        instance value of portAdditionalOperStatus
        upon port errordisable issues."

    ::= { ciscoIfCapability 11 }

ciscoIfCapabilityV5R015 AGENT-CAPABILITIES
    PRODUCT-RELEASE "MGX8850 Release 5.0.15"
    STATUS          current
    DESCRIPTION
        "IF MIB capabilities for Voice Switch
        Service Module (VXSM) 5.0.15"

    SUPPORTS        IF-MIB
    INCLUDES        { ifGeneralInformationGroup }
    VARIATION       ifTableLastChange
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifPhysAddress
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifNumber
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifAdminStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2)
                    }
    DESCRIPTION
        "For ifType propAtm (197), only up(1) is supported.
        This object is not supported if the
        ifType is sonetVT(51) or lapd(24)."

    VARIATION       ifOperStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2)
                    }
    DESCRIPTION
        "For ifType propAtm (197), not all states
        can be detected.
        This object is not supported if the ifType
        is sonetVT(51) or propAtm (197) or lapd(24)."

    VARIATION       ifOperStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2),
                        testing(3),
                        notPresent(6),
                        lowerLayerDown(7)
                    }
    DESCRIPTION
        "For ifType propAtm (197), not all states
        can be detected.
        For ifType sonetVT(51) only up(1), down(2) and
        lowerLayerDown(7) are detected."

    VARIATION       ifType
    DESCRIPTION
        "Only support the following ifType:
        sonet(39)
        sonetPath(50)
        ds3(30)
        vtPath(51)
        ds1(18)
        propAtm(197)
        AtmVciEp(194)
        lapd(77)"

    VARIATION       ifLastChange
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifLastChange
    DESCRIPTION
        "The value does not reflect the change in
        the operational status of the interface.
        The value zero is returned."

    VARIATION       ifLinkUpDownTrapEnable
    ACCESS          read-only
    DEFVAL          { disabled }
    DESCRIPTION
        "Write operation not supported."

    VARIATION       ifLinkUpDownTrapEnable
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifAlias
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    VARIATION       ifConnectorPresent
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported."

    ::= { ciscoIfCapability 12 }

ciscoIfCapabilityIOSXRV2R0CRS1 AGENT-CAPABILITIES
    PRODUCT-RELEASE "Cisco IOS XR 2.0 for CRS-1"
    STATUS          current
    DESCRIPTION
        "IF-MIB capabilities for Cisco IOS
        XR in releases 2.0"

    SUPPORTS        IF-MIB
    INCLUDES        {
                        ifGeneralGroup,
                        ifStackGroup,
                        ifGeneralInformationGroup,
                        ifFixedLengthGroup,
                        ifHCFixedLengthGroup,
                        ifPacketGroup,
                        ifHCPacketGroup,
                        ifVHCPacketGroup,
                        ifStackGroup2,
                        ifCounterDiscontinuityGroup
                    }
    VARIATION       ifPhysAddress
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifPromiscuousMode
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifConnectorPresent
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    ::= { ciscoIfCapability 13 }

ciscoIfCapabilityACSWV03R000 AGENT-CAPABILITIES
    PRODUCT-RELEASE "ACSW (Application Control Software) 3.0
                    for Application Control Engine (ACE) 
                    Service Module."
    STATUS          current
    DESCRIPTION
        "IF-MIB capabilities for Cisco ACSW 3.0."

    SUPPORTS        IF-MIB
    INCLUDES        {
                        ifGeneralInformationGroup,
                        ifFixedLengthGroup,
                        ifHCFixedLengthGroup,
                        ifPacketGroup,
                        ifHCPacketGroup,
                        linkUpDownNotificationsGroup
                    }
    VARIATION       ifAdminStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2)
                    }
    ACCESS          read-only
    DESCRIPTION
        "Only up(1) and down(2) states are supported.
        Set operation not allowed."

    VARIATION       ifOperStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2)
                    }
    DESCRIPTION
        "Only up(1) and down(2) states are supported."

    VARIATION       ifLinkUpDownTrapEnable
    ACCESS          read-only
    DESCRIPTION
        "Set operation not allowed."

    VARIATION       ifAlias
    ACCESS          read-only
    DESCRIPTION
        "Maximum length supported is 240 characters.
        Set operation not allowed."

    VARIATION       ifPromiscuousMode
    SYNTAX          TruthValue
    ACCESS          read-only
    DESCRIPTION
        "The only value supported is false(2)."

    VARIATION       linkUp
    DESCRIPTION
        "A linkUp notification signifies that the sending
        protocol entity recognizes that one of the
        communication links represented in the agent's
        configuration has come up. By default all
        varbinds listed under the OBJECTS clause
        are included in the notification PDU. When a
        new configuration command 'snmp-server trap link
        ietf' is set, varbinds ifType, ifName,
        clogOriginIDType, clogOriginID are not included
        in the notification PDU."

    VARIATION       linkDown
    DESCRIPTION
        "A linkDown notification signifies that the sending
        protocol entity recognizes a failure in one of
        the communication links represented in the
        agent's configuration.  By default all
        varbinds listed under the OBJECTS clause
        are included in the notification PDU. When a new
        configuration command 'snmp-server trap link
        ietf' is set, varbinds ifType, ifName,
        clogOriginIDType, clogOriginID are not included
        in the notification PDU."

    ::= { ciscoIfCapability 14 }

ciscoIfCapabilityCTSV100 AGENT-CAPABILITIES
    PRODUCT-RELEASE "Cisco TelePresence System (CTS) 1.0.0"
    STATUS          current
    DESCRIPTION
        "IF-MIB capabilities for CTS 1.0.0"

    SUPPORTS        IF-MIB
    INCLUDES        {
                        ifGeneralInformationGroup,
                        ifFixedLengthGroup,
                        ifPacketGroup
                    }
    VARIATION       ifLastChange
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifLinkUpDownTrapEnable
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifConnectorPresent
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifHighSpeed
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifName
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifAlias
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifTableLastChange
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifInUnknownProtos
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifInMulticastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifInBroadcastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifOutMulticastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifOutBroadcastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifPromiscuousMode
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    ::= { ciscoIfCapability 15 }

ciscoIfCapabilityCTMV1000 AGENT-CAPABILITIES
    PRODUCT-RELEASE "Cisco TelePresence Manager (CTM) 1.0.0.0"
    STATUS          current
    DESCRIPTION
        "IF-MIB capabilities for CTM 1.0.0.0"

    SUPPORTS        IF-MIB
    INCLUDES        {
                        ifGeneralInformationGroup,
                        ifFixedLengthGroup,
                        ifPacketGroup
                    }
    VARIATION       ifLastChange
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifLinkUpDownTrapEnable
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifConnectorPresent
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifHighSpeed
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifName
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifAlias
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifTableLastChange
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifInUnknownProtos
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifInMulticastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifInBroadcastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifOutMulticastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifOutBroadcastPkts
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    VARIATION       ifPromiscuousMode
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    ::= { ciscoIfCapability 16 }

ciscoIfCapabilityIOSXRV3R4CRS1 AGENT-CAPABILITIES
    PRODUCT-RELEASE "Cisco IOS XR 3.4 for CRS-1"
    STATUS          current
    DESCRIPTION
        "IF-MIB capabilities for Cisco IOS
        XR in releases 3.4"

    SUPPORTS        IF-MIB
    INCLUDES        {
                        ifGeneralGroup,
                        ifStackGroup,
                        ifGeneralInformationGroup,
                        ifFixedLengthGroup,
                        ifHCFixedLengthGroup,
                        ifPacketGroup,
                        ifHCPacketGroup,
                        ifVHCPacketGroup,
                        ifStackGroup2,
                        ifCounterDiscontinuityGroup,
                        ifRcvAddressGroup
                    }
    VARIATION       ifPhysAddress
    ACCESS          not-implemented
    DESCRIPTION
        "Not supported"

    ::= { ciscoIfCapability 17 }

ciscoIfCapabilityc4710aceVA1R700 AGENT-CAPABILITIES
    PRODUCT-RELEASE "ACSW (Application Control Software) A1(7)
                     for ACE 4710 Application Control Engine 
                     Appliance"
    STATUS          current
    DESCRIPTION
        "IF-MIB capabilities for Cisco ACSW A1(7)"

    SUPPORTS        IF-MIB
    INCLUDES        {
                        ifGeneralInformationGroup,
                        ifFixedLengthGroup,
                        ifHCFixedLengthGroup,
                        ifPacketGroup,
                        ifHCPacketGroup,
                        linkUpDownNotificationsGroup
                    }
    VARIATION       ifAdminStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2)
                    }
    ACCESS          read-only
    DESCRIPTION
        "Only up(1) and down(2) states are supported.
        Set operation not allowed."

    VARIATION       ifOperStatus
    SYNTAX          INTEGER  {
                        up(1),
                        down(2)
                    }
    DESCRIPTION
        "Only up(1) and down(2) states are supported."

    VARIATION       ifLinkUpDownTrapEnable
    ACCESS          read-only
    DESCRIPTION
        "Set operation not allowed."

    VARIATION       ifAlias
    ACCESS          read-only
    DESCRIPTION
        "Maximum length supported is 240 characters.
        Set operation not allowed."

    VARIATION       ifPromiscuousMode
    SYNTAX          TruthValue
    ACCESS          read-only
    DESCRIPTION
        "The only value supported is false(2)."

    VARIATION       linkUp
    DESCRIPTION
        "A linkUp notification signifies that the sending
        protocol entity recognizes that one of the
        communication links represented in the agent's
        configuration has come up. By default all
        varbinds listed under the OBJECTS clause
        are included in the notification PDU. When a
        new configuration command 'snmp-server trap link
        ietf' is set, varbinds ifType, ifName,
        clogOriginIDType, clogOriginID are not included
        in the notification PDU."

    VARIATION       linkDown
    DESCRIPTION
        "A linkDown notification signifies that the sending
        protocol entity recognizes a failure in one of
        the communication links represented in the
        agent's configuration.  By default all
        varbinds listed under the OBJECTS clause
        are included in the notification PDU. When a new
        configuration command 'snmp-server trap link
        ietf' is set, varbinds ifType, ifName,
        clogOriginIDType, clogOriginID are not included
        in the notification PDU."

    ::= { ciscoIfCapability 18 }

END